BCA licensing

BCA workheads explained: CW, CR, ME, TR and RW.

A workhead is the label BCA puts on what your firm actually does. Pick the right one and your registration covers your real scope of work, your track record counts and your Work Permits follow. Pick the wrong one and you have paid a fee to be registered for work you do not do. This is the full list, group by group, with the financial, track record and personnel requirements at every grade.

By Veronica Tan, Managing Director  ·  Updated July 2026. Figures are from BCA's June 2025 Specific Registration Requirements. BCA revises these; we confirm the current criteria for your workhead before applying.

BCA's Contractors Registration System organises about 50 workheads into five groups. CW covers main contractor work, general building and civil engineering. CR covers construction-related specialist works such as demolition, piling, waterproofing and interior finishing. ME covers mechanical and electrical work, from air-conditioning to electrical engineering to lifts. TR covers narrow trades used by sub-contractors, such as formwork and tiling. RW covers regulatory registration for window, lift, escalator and mechanised car park contractors. You register in the workhead or workheads that best describe your main business activities, at a grade your financials support. Since 1 June 2025, being registered in a workhead is also what allows a construction firm to hire and renew foreign construction workers.

A workhead is what you do. A grade is how big you are.

These two get muddled constantly, so it is worth separating them before anything else.

The workhead is the activity. ME01 is air-conditioning, refrigeration and ventilation works. CR13 is waterproofing installation. CW01 is general building. It describes the kind of work your firm is registered to carry out, and nothing else.

The grade is the capacity. It reflects your paid-up capital, your net worth and your completed track record, and in public sector tendering it sets your tendering limit. In the CR and ME groups grades run from L1 at the entry level up to L6. In CW they run from C3 at the entry level up through C2, C1, B2, B1 and A2 to A1. TR has a single grade with no ladder at all.

So a firm might hold ME01 at L3 and ME05 at L1 at the same time: two activities, two capacities. That combination is completely normal.

One detail that surprises people: in every SRR the requirement is printed in a single Financial column, and BCA's note states that both minimum paid-up capital and minimum net worth must meet that figure. So when the table below says $150,000 at L3, it means $150,000 of paid-up capital and $150,000 of net worth, not one or the other.

The five groups at a glance

The five CRS workhead groups. Source: BCA Specific Registration Requirements, June 2025 editions.
GroupWhat it coversGradesEntry grade
CW, Construction WorkheadsMain contractor work: general building and civil engineeringC3, C2, C1, B2, B1, A2, A1C3
CR, Construction-Related WorkheadsSpecialist works and services supporting the main contractorSingle Grade, L1 to L6L1 or Single Grade
ME, Mechanical and Electrical WorkheadsBuilding services: air-conditioning, electrical, plumbing, fire protection, liftsL1 to L6L1
TR, Trade HeadsNarrow trades, generally used by sub-contractorsOne grade only, no ladderNot applicable
RW, Regulatory WorkheadsRegulatory registration for windows, lifts, escalators and mechanised car parksNot gradedNot applicable

Two groups behave differently from the rest and catch people out. TR has no grades, so there is nothing to aim up at. And RW is not really a capacity ladder at all: it is regulatory permission to do work that is separately controlled, which is why an ME09 lift firm still needs the matching RW registration on top.

CW: Construction Workheads

Only two workheads sit in this group, and they are the largest ones in the system.

  • CW01 General Building
  • CW02 Civil Engineering

CW is where main contractors live. The grades are the C, B and A series, and the jump between them is steep: the difference between C3 and A1 is $50,000 of capital against $15 million.

CW01 and CW02 requirements by grade. Financial figures apply to both paid-up capital and net worth. Source: CW SRR, June 2025.
GradeFinancialTrack record, past 3 yearsPersonnel
C3SGD 50,000SGD 300,0001 RP, P or T
C2SGD 100,000SGD 1m1 RP or P, or 2 T
C1SGD 300,000SGD 3m1 RP or P, plus 1 T
B2SGD 1mSGD 10m3 personnel, at least 1 RP and 1 ACCP, SDCP or CCPP
B1SGD 3mSGD 30m6 personnel, at least 2 RP and 1 SDCP or CCPP
A2SGD 6.5mSGD 65m12 personnel, at least 4 RP and 1 SDCP or CCPP
A1SGD 15mSGD 150m24 personnel, at least 8 RP and 1 SDCP or CCPP

RP, P and T are BCA's personnel categories, and they are not interchangeable. We break them down properly in our guide to the Approved Person, the Technical Controller and BCA's personnel categories. In short: RP is a Registerable Professional, P is a Professional with a relevant degree, and T is a Technician with a relevant diploma.

CR: Construction-Related Workheads

This is the largest group by count and the one most small specialist firms belong to.

The 19 CR workheads. Source: CR SRR, June 2025.
CodeWorkheadCodeWorkhead
CR01Minor Construction WorksCR10BPrecast Concrete Production
CR02Corrosion ProtectionCR11Signcraft Installation
CR03DemolitionCR12Ground Support and Stabilisation Works
CR04Fencing and IronworksCR13Waterproofing Installation
CR05Concrete RepairsCR14Asphalt Works and Road Marking
CR06Interior Decoration and Finishing WorksCR15Site Investigation, Instrumentation and Monitoring
CR07Cable and Pipe Laying, Road ReinstatementCR16Curtain Walls
CR08Piling WorksCR17Windows
CR09Repairs and RedecorationCR18Doors
CR10AAutomated Precast Concrete Production  

If you run a renovation or interior fit-out business, CR06 is almost certainly your workhead. If you waterproof, CR13. If you demolish, CR03.

CR requirements by grade. Financial figures apply to both paid-up capital and net worth. Source: CR SRR, June 2025.
GradeFinancialTrack record, past 3 yearsPersonnel
Single GradeSGD 50,000SGD 300,000, or SGD 2m for CR10A1 T
L1SGD 50,000SGD 300,0001 T
L2SGD 50,000SGD 1m1 T with 3 years of relevant experience
L3SGD 150,000SGD 3m2 T
L4SGD 250,000SGD 5m2 T, one with 5 years of experience
L5SGD 500,000SGD 10m1 P, or 2 T with one at 8 years of experience
L6SGD 1.5mSGD 30m2 P with 5 years of experience, including 1 SDCP

Single Grade applies to CR01, CR03, CR10A, CR15, CR17 and CR18. These workheads have no ladder: you are either registered or you are not. CR10A is the odd one out on money as well, needing SGD 2m of paid-up capital with no net worth requirement attached.

ME: Mechanical and Electrical Workheads

This is the group that matters most to the trades we are asked about most often: air-conditioning, electrical, plumbing and fire protection.

The 14 ME workheads. Note there is no ME14; the numbering skips it. Source: ME SRR, June 2025.
CodeWorkheadCodeWorkhead
ME01Air-Conditioning, Refrigeration and Ventilation WorksME08Internal Wiring for Telecommunications
ME02Building Automation, Industrial and Process Control SystemsME09Lift, Escalator and Mechanised Car Parking Systems
ME03Solar PV and System IntegrationME10Line Plant Cabling and Wiring for Telecommunications
ME04Communication and Security SystemsME11Mechanical Engineering
ME05Electrical EngineeringME12Plumbing, Gas Piping and Sanitary Works
ME06Fire Prevention and Protection SystemsME13Traffic Light Systems
ME07High and Low Tension Overhead Line InstallationME15Integrated Building Services

ME has no Single Grade. Every ME workhead from ME01 to ME13 runs on the L1 to L6 ladder.

ME01 to ME13 requirements by grade. Financial figures apply to both paid-up capital and net worth. Source: ME SRR, June 2025.
GradeFinancialTrack record, past 3 yearsPersonnel
L1SGD 50,000SGD 300,0001 T with 3 years of relevant experience
L2SGD 50,000SGD 1m1 T with 3 years of relevant experience
L3SGD 150,000SGD 3m2 T
L4SGD 250,000SGD 5m, including a single contract of SGD 500,0002 T, one with 5 years of experience
L5SGD 500,000SGD 10m, including a single contract of SGD 1m1 P, or 2 T with one at 8 years of experience
L6SGD 1.5mSGD 30m, with sub-thresholds for Singapore projects, main contracts and single contracts2 P with 5 years of experience, including 1 SDCP except for ME07 and ME13

ME15, Integrated Building Services, works differently. It starts at L2, not L1, and it is only open to firms that already hold other ME registrations: at L2 you need ME01 and ME05 both at L2 plus one further ME workhead at L2. It also requires personnel holding a specific building services qualification that BCA labels MEC.

Trade licences that sit on top of the workhead

Three ME workheads carry requirements that come from outside BCA, and missing them is a common reason an application stalls.

  • ME05, Electrical Engineering. An EMA-licensed electrician can count as a T for Grades L1 and L2 only. An EMA electrical engineer or technician can count as a T for Grades L3 to L5. This is a substitution allowance, not an extra requirement.
  • ME12, Plumbing, Gas Piping and Sanitary Works. Requires a PUB plumber licence or an EMA gas service worker licence.
  • ME09, Lift, Escalator and Mechanised Car Parking Systems. ME09 on its own is not enough. You must also obtain the relevant Regulatory Workhead from BCA before carrying out registrable activities.

Separately, bizSAFE Level 3 or ISO 45001 is required at Grade L6 only, and only for ME01, ME02, ME05, ME06, ME11 and ME12.

TR: Trade Heads

Ten trades, one set of requirements, no grades. TR is designed for sub-contractors supplying labour and trade work to main contractors.

The 10 TR trade heads. Source: TR SRR, June 2025.
CodeTradeCodeTrade
TR01FormworkTR06Ceiling Work
TR02Steel Reinforcement WorkTR07Tile, Marble and Stone Work
TR03Concreting WorkTR08Timber, Vinyl and Laminate Flooring Work
TR04Drywall InstallationTR09Plastering and Skimming
TR05Precast InstallationTR10Ironmongery and Metalwork

The requirements are the same for all ten: paid-up capital of SGD 50,000, a track record of SGD 300,000 over the past three years, and one person with a recognised degree or diploma in a building-related field. Trade diplomas from BCA Academy or equivalent are accepted. Notably, TR carries no net worth requirement at all, which makes it the most accessible group in the system for a young firm.

RW: Regulatory Workheads

RW is a different animal. These are not capacity grades; they are regulatory permissions to work on equipment that is separately controlled under the Building Control Act.

The RW workheads. The A and B suffixes separate installation from maintenance. Source: RW SRR and BCA's Fixed Installation Contractor registration framework.
CodeWorkhead
RW01Window Contractors
RW02A / RW02BLift Installation Contractor / Lift Maintenance Contractor
RW03A / RW03BEscalator Installation Contractor / Escalator Maintenance Contractor
RW04A / RW04BMechanised Car Parking Systems Installation / Maintenance Contractor

RW01 is the only one with figures in the SRR itself: paid-up capital of SGD 5,000, no track record required, and two personnel, where "personnel" here means someone holding an HDB Certificate of Attendance in Safety of Windows. Window installers also need twelve months of local experience before they are eligible for that training.

RW02 to RW04 now sit under the Fixed Installation Contractor framework, which requires paid-up capital of SGD 50,000 and a number of qualified persons that varies with the scope. Lift maintenance covering all lift types needs three qualified persons; lift maintenance limited to lifts under 5 m/s needs two; home lifts in residential units need one. Escalator maintenance needs two, and installation activities generally need one.

One thing worth clearing up, because it gets misread as a capability tier: lift and escalator maintenance registrations are split into Bands 1, 2 and 3, and those bands are application fee bands based on how many units you already maintain, not grades. Band 1 is 1,000 units and above, Band 2 is 500 to 999, and Band 3 is up to 499.

Choosing the right workhead

Three rules cover most cases.

Describe what you actually do, not what you hope to do. BCA assesses the application against evidence of completed work. A firm that has done interior fit-out and applies under CW01 because it sounds bigger will be asked awkward questions, and the fit-out projects will not count towards general building.

Track record is assessed per workhead. This is the single most consequential rule in the system. Work completed under CR06 counts towards CR06. It does not count towards ME05. So the workhead you choose also decides which of your past projects you are allowed to use, and that in turn decides which grade you can reach.

Check whether an outside licence is attached. Plumbing needs the PUB or EMA licence. Lifts need the matching RW registration. Discovering that after you have submitted costs weeks.

Holding more than one workhead

You can register in as many workheads as your business genuinely covers, and many firms should. An M and E contractor that installs air-conditioning and also does the electrical work needs ME01 and ME05, because a single registration does not stretch to cover both.

The cost consideration is that BCA charges its registration fee per workhead, so three workheads means three fees. Since track record is also assessed per workhead, and since it takes three years of completed work to build one, the practical advice is to map out every workhead you will need at the outset rather than adding them one at a time over several years. Our BCA CRS registration service prices additional workheads at SGD 688 each alongside the first for exactly this reason.

Questions people ask

How many BCA workheads are there? +

About 50, spread across five groups: 2 in CW, 19 in CR, 14 in ME, 10 in TR, and 7 in RW counting the A and B variants separately. You register in the workhead or workheads that best describe your firm's main business activities.

What is the difference between a workhead and a grade? +

The workhead is what you are registered to do, such as ME01 for air-conditioning work. The grade is your registered capacity, based on paid-up capital, net worth and completed track record, and it sets your public sector tendering limit. CR and ME grade from L1 to L6, CW grades from C3 up to A1, TR has a single grade and RW is not graded.

Which workhead does a renovation or interior fit-out company need? +

CR06, Interior Decoration and Finishing Works, in most cases. Firms doing smaller general works may fall under CR01 Minor Construction Works, and those supplying specific trades to main contractors may belong in TR, for example TR07 for tile and stone work. The correct answer depends on the contracts you actually hold, which is what an eligibility assessment establishes.

Which workhead does an air-conditioning company need? +

ME01, Air-Conditioning, Refrigeration and Ventilation Works. At Grade L1 that means SGD 50,000 in paid-up capital and net worth, SGD 300,000 of ME01 track record over three years, and one Technician with three years of relevant experience. Firms that also carry out the electrical work usually need ME05 alongside it.

Can I register in more than one workhead at the same time? +

Yes, and it is usually cheaper to do so. BCA charges its registration fee per workhead, and track record is assessed per workhead, so identifying everything you need at the outset avoids paying twice and waiting another three years to build the record for the second one.

Is net worth required for every workhead group? +

No. In CW, CR and ME the SRR prints one Financial figure per grade and BCA's note requires both paid-up capital and net worth to meet it. TR has no net worth requirement at all, only SGD 50,000 of paid-up capital. CR10A is a further exception: SGD 2m of paid-up capital with no net worth requirement.

Do the RW bands mean the same thing as grades? +

No. Bands 1, 2 and 3 apply only to lift and escalator maintenance registration, and they are application fee bands set by how many units you already maintain: 1,000 and above is Band 1, 500 to 999 is Band 2, and up to 499 is Band 3. What actually varies a lift maintenance contractor's capability is the scope tier, which determines how many qualified personnel you need.

Not sure which workhead fits your business?

Book a free eligibility assessment. We will match what you actually build, install or maintain to the correct workhead and grade, before you pay BCA anything.